Skip to main content

Table 2 Summary of reported performance metrics from recent neonate survival research using traditional vaginal implant transmitters relative to results of this study (bottom row) using radio-linked vaginal implant transmitters (VITs) in Sussex County, Delaware, USA

From: An initial performance review of vaginal implant transmitters paired with GPS collars

Study area

VITs deployed

Expelled at birth site

Neonates located

Neonates/birth site

Premature expulsions

>1 Neonate at birth site

Colorado [3]

47

36 (77%)

60

1.4

11 (23%)

Colorado [8]

147

59 (40%)

89

1.5

34 (23%)

Louisiana [34]

102

46 (45%)

70

1.5

3 (3%)

24 (52%)

Missouri [38]

80

64 (80%)

89

1.4

Alabama [41]

16

11 (69%)

14

1.3

1 (6%)

Connecticut [42]

103

56 (54%)

79

1.4

25 (45%)

Kentucky [44]

54

45 (83%)

61

1.4

1 (2%)

Delaware

44

26 (59%)

44

1.7

12 (27%)

18 (69%)